Tags:

The main application for the E5AS is in boilers. Compared with other heat exchangers, central heating water circuits using the E5AS experience a lower pressure drop. The E5AS is thermally long, which makes it particularly suitable for condensing boiler systems, yet it remains physically short, for compactness.

The environmentally friendly E5AS has an innovative new plate pattern that enable it to transfer more heat using less material.

The E5AS is capable of handling a water flow rate up to 50 l/min.

Platform Compatible Version Certified to
IFC IFC 2X3 2 1.3
Revit Revit 2016 + 3 2.0

  • Properties and values
  • More BIM objects
  • What's Changed?

Properties and values

COBie
NBS_General
NBS_Data
BPHEWeight
2
ConnectionsCentresDistanceHorizontal
40
ConnectionsCentresDistanceVertical
154
ConnectionsLength
12.1
ConnectionsLengthOptions
12.1 mm
CornerRadius
16
InnerCircuitMaximumWorkingPressureAtTestTemperature1
1000000
InnerCircuitTestPressure
2000000
InternationalContactInformation
www.swep.net/​en/​contact/​Pages/​default.aspx
LeadingPlateThickness
7
MaterialBrazing
Pure Copper
MaterialGaskets
n/a
MaterialStandardConnection
Stainless steel, 1.4401
MaterialStandardPlates
Stainless steel, 1.4401
MaximumNumberOfPlates
40
MaximumTemperature
100
MinimumTemperature
0
Output
To determine Output please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
PortSize
16
PrimaryMediumFlowRate
To determine PrimaryMediumFlowRate please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
PrimaryMediumFluid
To determine PrimaryMediumFluid please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
PrimaryMediumInletTemperature
To determine PrimaryMediumInletTemperature please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
PrimaryMediumOutletTemperature
To determine PrimaryMediumOutletTemperature please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
PrimaryMediumPressureLoss
To determine PrimaryMediumPressureLoss please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
PrimaryMediumWorkingPressure
To determine PrimaryMediumWorkingPressure please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
SecondaryCircuitMaximumWorkingPressureAtTestTemperature1
1000000
SecondaryCircuitTestPressure
2000000
SecondaryMediumFlowRate
To determine SecondaryMediumFlowRate please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
SecondaryMediumFluid
To determine SecondaryMediumFluid please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
SecondaryMediumInletTemperature
To determine SecondaryMediumInletTemperature please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
SecondaryMediumOutletTemperature
To determine SecondaryMediumOutletTemperature please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
SecondaryMediumPressureLoss
To determine SecondaryMediumPressureLoss please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
SecondaryMediumWorkingPressure
To determine SecondaryMediumWorkingPressure please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
SSPCalculationSoftware
www.swep.net/​en/​products_​solutions/​ssp_​calculation_​software/​Pages/​default.aspx
TestTemperature1
373.15
TotalThicknessOfPlates
84.46
Pset_HeatExchangerTypeCommon
Pset_HeatExchangerTypePlate

More BIM objects

What's Changed?

19/01/2017

Changes to reflect updates to the NBS BIM Object Standard v1.3

  • Removal of Uniclass2 property
  • Addition of Uniclass 2015 properties