NBS National BIM Library

Rada Sense - Bidet Kit T3

Rada Sense - Bidet Kit T3

Rada - Kohler Mira Ltd
Cromwell Road
Cheltenham
Gloucestershire
GL52 5EP

Tel +44 (0)844 571 1777

Need specialist advice?
Get technical help
 

Rada Sense - Bidet Kit T3

Concealed digital mixing valve for bidet, offering programmable maximum, minimum and default temperatures, duty flush and thermal disinfection with data-logging capabilities.
Supplied complete with programmable software, power supply, check valves and strainers. Wall mounted control panel offering infra-red no-touch controls for flow and temperature adjustment and programmable timed flow control.

With deck mounted bidet spout for ‘over the rim’ delivery supplied with 5 l/min flow regulator.

  • ƒBuildcert TMV3 Scheme Approved.
  • ƒƒWRAS Approved.
  • ƒƒRemotely located valve (up to 3 m).
  • ƒƒThe world’s first digital mixing valve for commercial use.
  • ƒƒSets new standards of hygiene.
  • ƒƒNo-touch ON/OFF and temperature control.
  • ƒƒProgrammable flow times and temperatures.
  • ƒƒProgrammable ‘duty flushing’.
  • ƒƒSecure thermal disinfection with data-logging.
  • ƒƒValve information and usage data.
  • ƒƒIncorporating T-logic™ digital intelligence.
Platform Compatible Version Certified to
AECOsim AECOsim - 1.0 -
IFC IFC 2X3 3 1.3
Revit Revit 2015 + 3 1.3

Download

Rada - Kohler Mira Ltd
Cromwell Road
Cheltenham
Gloucestershire
GL52 5EP

Tel +44 (0)844 571 1777

Need specialist advice?
Get technical help
 
  • Properties and values
  • More information
  • More BIM objects
  • What's Changed?

Properties and values

COBie
NBS_General
NBS_Data
Certification
Buildcert TMV3 Scheme Approved, WRAS Approved, BEAB approved
ColdWaterTemperatureRange
1-20°C
ControlPanelCableLength
3 m supplied (6 m max)
ControlPanelSize
234 x 120 x 26 mm
DigitalMixingValveSize
511 x 188 x 86 mm
FactoryPresetDisinfection
Minimum 5 min at 60°C
FactoryPresetDutyFlushCycle
2 min
FactoryPresetDutyFlushWaitingPeriod
12 h
FactoryPresetFlowTime
15 s
FactoryPresetTemperatureRange
Minimum 30°C, maximum 38°C, default 36°C
HotWaterTemperatureRange
50-65°C (85°C during disinfection)
IntegralAccessories
Pocket PC (PDA)
MaximumHumidity
95%
MaximumStaticPressure
10 bar
MaximumWaterSupplyTemperature
41°C
MinimumBlendTemperatureDifferential
2°C
MinimumFlowRate
4 L/min at <5 bar, 6 L/min at >5 bar
MinimumPressureLoss
0.2 bar
OperatingTemperature
1-40°C
OptimumThermostaticControlRange
30-50°C
ProgrammableDisinfection
Minimum 0-5 minutes at 60-85°C
ProgrammableDutyFlushCycle
1-59 min
ProgrammableDutyFlushWaitingPeriod
1-983 h
ProgrammableFlowTime
5 s - 60 min
ProgrammableTemperatureRange
Minimum 30-47°C, maximum 33-50°C, default 30-50°C
TemperatureStability
U+00B11°C
Weight
We
Pset_ElectricalDeviceCommon
Pset_FlowMeterTypeCommon
Pset_FlowMeterTypeWaterMeter
Pset_ValveTypeCommon
Pset_ValveTypeFaucet
Pset_ValveTypeMixing

More information

  • NBS specification data
    Case studies and technical literature
  • More BIM objects

    What's Changed?

    13/03/2017

    Changes to reflect updates to the NBS BIM Object Standard v1.3

    • Removal of Uniclass2 property
    • Addition of Uniclass 2015 properties
    • Addition of COBie Category property value

    Objects have also been updated to Revit 2015

    Terms and conditions

    Please agree to the updated terms and conditions

    Thank you, your registration was complete
    Thank you
    Your query has been sent.

    A technical consultant from will be in touch soon.
    Manufacturers using NBS National BIM Library adhere to our code of conduct.