NBS National BIM Library

Kingspan Thermafloor TF70

Kingspan Thermafloor TF70

Pembridge
Leominster
Herefordshire
HR6 9LA

Tel +44 (0)1544 387601

Need specialist advice?
Get technical help
 

Kingspan Thermafloor TF70

Insulation for solid concrete and suspended ground floors

  • High performance rigid thermoset insulation – thermal conductivity 0.022 W/m∙K.
  • Can reduce the cost of related items – soil removal, service connections.
  • Easy to handle and install.
  • Ideal for new build and refurbishment.
Platform Compatible Version Certified to
AECOsim AECOsim - 1.0 -
ARCHICAD ARCHICAD - 1.0 -
IFC IFC 2X3 5 1.3
Revit Revit 2015 + 5 1.3
Vectorworks Vectorworks - 1.0 -

Download

Pembridge
Leominster
Herefordshire
HR6 9LA

Tel +44 (0)1544 387601

Need specialist advice?
Get technical help
 
  • Properties and values
  • More information
  • More BIM objects
  • What's Changed?

Properties and values

COBie
NBS_General
NBS_Data
Behavior
Isotropic
BoardProperties
n/a
BoardThickness
n/a
Certification
BBA certificate 07/4450
CompressiveStrength
140 kPa
CrossSection
Uniform thickness
Density
32 kg/m³
Edges
Square
ElectricalResistivity
0
Emmissivity
0.06
Facing
Low emissivity composite foil facing
FMApproved
n/a
GlobalWarmingPotential
Less than 5
GreenGuideRating
A+
Insulation
High performance rigid thermoset polyisocyanurate (PIR) insulant
MaximumOperatingTemperature
90 °C
OzoneDepletionPotential
Zero
Permeability
0 ng/(PaU+2022sU+2022m²)
Porosity
0
RecycledContent
n/a
Reflectivity
0
SpecificHeat
1.4 J/(gU+2022°C)
StandardLength
2400 mm
StandardThickness
160 mm
StandardWidth
1200 mm
ThermalConductivity
0.022 W/(mU+2022°K)
ThermalResistance
7.25 m²K/W
ThicknessOptions
Refer to Kingspan InsulationU+2019s technical department for thickness availability and U-value calculations U+2013call 01544 387 382 or email  technical@kingspaninsulation.co.uk
WaterVapourTransmission
100 MNs/g
Pset_CoveringCommon
Pset_MaterialProperties

More information

  • NBS specification data
  • More BIM objects

    What's Changed?

    02/03/2017

    Changes to reflect updates to the NBS BIM Object Standard v1.3

    • Removal of Uniclass2 property
    • Addition of Uniclass 2015 properties
    • Addition of COBie Category property value

    Objects have also been updated to Revit 2015

    Terms and conditions

    Please agree to the updated terms and conditions

    Thank you, your registration was complete
    Thank you
    Your query has been sent.

    A technical consultant from will be in touch soon.
    Manufacturers using NBS National BIM Library adhere to our code of conduct.