Standard Grade Celcon Plus Block - NBS National BIM Library

Standard Grade Celcon Plus Block

Standard Grade Celcon Plus Block

Download

This object complies to standards for the UK, but it may also be suitable for use in other locations.

Tags:

Standard grade blocks are multi purpose and may be used above and below DPC level. They are also suitable for separating walls and internal partition as well as inner and outer leaf of external walls.

Platform Compatible Version Certified to
AECOsim AECOsim - 1 -
ARCHICAD ARCHICAD - 1 -
IFC IFC 2X3 2 1.3
Revit Revit 2016 + 5 2.0
Vectorworks Vectorworks - 1 -

  • Properties and values
  • More information
  • More BIM objects
  • What's Changed?

Properties and values

COBie
NBS_General
NBS_Data
AirTightness
0.1 m³/hour/m²
BlockCategory
Category ||
BlockType
Aircrete block
CoefficientofLinearExpansion
8 x 10-6/K
Configuration
Group 1
DeclarationOfPerformance
www.hhcelcon.co.uk/​files/​download/​113-CEHHUK-StandardDOP002.pdf
Density
600 kg/m³
DryingShrinkage
0.4 mm/m
FreezeThawResistance
Frost Resistant - ref BBA Certificate 01-3816
MeanCompressiveStrength
3.6 N/mm²
MoistureMovement
0.4 mm/m in accordance with EN 771-4:2011
MortarYields
www.hhcelcon.co.uk/​files/​download/​141-TSD62-Mortar-Yields.pdf
PackagingSize
www.hhcelcon.co.uk/​files/​download/​153-TSD83-PACKS-sizes-and-weights.pdf
PredictedAcousticRating
Rw at 100 mm : 40.0 dB unfinished, 42.5 dB lightweight plaster, 45.8 dB, dense plaster
RecycledContent
80% (Reference WRAP website)
ServiceLifeDuration
BBA Certificate 01-3816 - Aircrete is a durable material. Walls will have a durability equivalent to that of traditional masonry (In excess of 60 years)
ServiceLifeType
BBA Certificate 01-3816 - Aircrete is a durable material. Walls will have a durability equivalent to that of traditional masonry (In excess of 60 years)
ShearBondStrength
0.15 N/mm2 with GPLM + 0.30 N/mm2 with TLM
SpecificHeatCapacity
1.05 kJ/kgK
SuitableFixings
www.hhcelcon.co.uk/​files/​download/​70-TSD20-Fixings.pdf
ThermalConductivity
0.15 W/mK at 3% moisture
ThermalTransmittanceNote
U-Value is not Appropriate - Conductivity Value =0.15 W/Mk - design value @3% moisture
ThicknessOptions
100 mm, 140 mm, 200 mm (other thicknesses available to order)
ThinLayerMortar
www.hhcelcon.co.uk/​files/​download/​109-CEHHUK-CelfixDOP010.pdf
ToleranceCategory
TLMA
VapourDiffusionResistanceFactor
10
VapourResistivity
50 MNs/gm
WaterAbsorptionByCapillarity
No Performance Declared
WaterVapourPermeability
5/10
Weight
10 kg
Pset_WallCommon

More information

  • NBS specification data
    Case studies and technical literature
  • More BIM objects

    What's Changed?

    19/01/2017

    Changes to reflect updates to the NBS BIM Object Standard v1.3

    • Removal of Uniclass2 property
    • Addition of Uniclass 2015 properties
    • Addition of COBie Category property value

    Objects have also been updated to Revit 2015