VilX-CPP Assist Call Pull Cord Plate

Select regional version:

Download

The object content is configured for use in UK, but it may also be suitable for use in other locations.

Tags:

The ceiling pull plate is used to activate the alarm; the ceiling pull plate should be mounted with the lowest ring pull 100mm from the floor. The ceiling pull plate consists of a single gang brushed stainless steel plate as standard with a blue halo indicator for the visual alarm. For simplicity all wiring is a standard two core cable, up to 6 pull cords can be connected on a single line, the wiring order of the plates is not fixed and therefore can be wired in any order to give total flexibility in the installation routes. Each plate has two sets of two part terminals allowing simple cable connections and also a complete first fix solution. There is no practical limit to the number of pull cords on a single line, with the last one pulled registering.

Platform Compatible Version Certified to
IFC IFC - 1 2.1
Revit Revit - 1 2.1

  • Properties and values
  • More BIM objects

Properties and values

IFC
IfcExportAs
IfcAlarmType
IfcExportType
NOTDEFINED
COBie
BOS_General
NBS_Data
BackBoxInformation
25 mm deep single gang flush back box or round corned metal surface box, a matching brushed stainless surface pattress is available
Mounting
Surface mounted
Supply
24VDC from controller
Pset_AlarmTypeCommon