VMZ Standing seam on rigid insulation

Select regional version:

Download

The object content is configured for use in UK, but it may also be suitable for use in other locations.

Tags:

Non vented warm roof system for buildings with humidity classes between 1 and 4 using VMZINC Plus. BBA certificate 12/4900 product sheet 1.

Platform Compatible Version Certified to
IFC IFC 2X3 1 1.3
Revit Revit 2016 + 2 2.0

  • Properties and values
  • More information
  • More BIM objects
  • What's Changed?

Properties and values

IFC
IfcExportAs
IfcRoofType
IfcExportType
FLAT_ROOF
COBie
NBS_General
NBS_Data
CrossJointsForm
n/a
EaveDetailsFixings
n/a
EaveDetailsForm
n/a
EnvironmentalProductDeclaration
n/a
FinishOptions
Natural Zinc PLUS, QUARTZ-ZINC PLUS, ANTHRA-ZINC PLUS, AZENGAR PLUS, PIGMENTO PLUS
GreenGuideRating
A+
HumityClassOptions
1-4 (dwellings with high occupancy, sport halls, etc)
InsulationOptions
PIR or mineral wool. All insulation materials must have a compression strength of minimum 50 kPa (0.5 kg/cm²), at a maximum 10% deformation and must be dimensionally stable at up to 100°C
InsulationType
Polyisocyanurate (PIR) foam board
LongitudinalJointsFastenersToSubstrate
n/a
LongitudinalJointsFixingBattenRollJoints
n/a
LongitudinalJointsFixingStandingSeamJoints
n/a
LongitudinalJointsForm
n/a
PitchOptions
3-60°
RidgeAndHipDetailsFixings
n/a
RidgeAndHipDetailsForm
n/a
SamplesRequired
n/a
SheetUnderlayFasteners
n/a
SheetUnderlayJointTreatment
n/a
SheetUnderlayMaterial
VMZINC Membrane
SheetUnderlayOptions
n/a
StructureOptions
Steel, plywood deck
SubstratePreparationFasteners
n/a
SubstratePreparationJointTreatment
n/a
SubstratePreparationRequirements
n/a
SubstrateType
n/a
SystemAccessories
n/a
ThirdPartyCertification
BBA certified - 12/4900 sheet 1
TimberCoresForBattenRollJointsCore
n/a
TimberCoresForBattenRollJointsFastenersToSubstrate
n/a
VapourControlLayerOptions
Aluminium foil-reinforced bituminous vapour barrier with a high water vapour resistance (minimum vapour resistance 4000 MNsg) installed with cold or hot glued joints. Higher performance vapour barriers may be required depending on the humidity class of the building
VapourControlLayerType
Aluminium foil-reinforced bituminous vapour barrier
VergeDetailsFixingBottomEdge
n/a
VergeDetailsFixingTopEdge
n/a
VergeDetailsForm
n/a
VergeDetailsJoints
n/a
VergeDetailsVergeZinc
n/a
Weight
Average 6 kg/m²
Zinc
VMZINC PLUS Standing Seam
Pset_RoofCommon

More information

  • NBS specification data
    Case studies and technical literature
  • More BIM objects

    What's Changed?

    8/21/2018

    Object upgraded to NBS BIM Object Standard v2.0.