StoVentec Glass

Select regional version:

Download

The object content is configured for use in UK, but it may also be suitable for use in other locations.

Tags:

StoVentec Glass can be used as an external rainscreen cladding system, and as an internal decorative option.

The system comprises a glass faced composite panel, thermal insulation and sub-construction. Tempered glass is adhered to a carrier board to produce an inseparable composite panel, which protects the substrate from rain. A circulating air layer is formed between the hung panel and the mineral wool insulation, mounted directly onto the substrate. Insulation on the outside of the construction keeps the wall warm and reduces the risk of condensation and minimizes temperature fluctuations.

The ventilated facade is available in many panel sizes and different surface colours and finishes, offering great aesthetic potential for facade designs on new build or refurbished buildings.

StoVentec Glass is the only UK glass rainscreen system with a BBA certificate for all standard applications and has passed stringent impact and bomb blast tests, demonstrating its suitability for use in high profile public spaces such as airports and train stations.

Platform Compatible Version Certified to
IFC IFC - 1 1.3
Revit Revit 2016 + 3 2.0

  • Properties and values
  • More BIM objects
  • What's Changed?

Properties and values

IFC
IfcExportAs
IfcWallType
IfcExportType
STANDARD
COBie
NBS_General
NBS_Data
Accessories
n/a
BreatherMembraneFasteners
n/a
BreatherMembraneMaterial
n/a
CavityBarriers
Cavity barriers as specified
CladdingPanelsFasteners
n/a
CladdingPanelsMaterial
Glass composite panel
FactoryFinish
n/a
Form
Robust slabs
InnerLeaf
20 mm carrier board made of expanded glass granulate
InsulationThicknessMinimum
n/a
InterlayerToGlassLeaves
n/a
ItemsToBeInsulated
Rainscreen cladding and curtain wall systems
LaminateGlassType
Safety glass
MaterialGrade
n/a
MaterialStandards
n/a
MidLeaf
Colour enamel
OuterLeaf
6 or 8 mm toughened safety glass
PerformanceRequirementsFireProtectionInsulation
n/a
PerformanceRequirementsFireProtectionIntegrity
n/a
PerformanceRequirementsFireProtectionRadiation
n/a
PerformanceRequirementsImpactResistance
Category B to BS8200, Class 1 to BS12600, Pass - Bomb Blast test
PerformanceRequirementsLight
n/a
PerformanceRequirementsSecurity
n/a
PerformanceRequirementsSolarControl
n/a
PerformanceRequirementsSoundAttenuation
n/a
PerformanceRequirementsThermalInsulation
n/a
PerformanceRequirementsTotalShadingCoefficient
n/a
RecycledContent
n/a
SecondarySupportStructureCarriers
Stainless Steel Wall Brackets with aluminium horizontal and vertical support profiles
SecondarySupportStructureFasteners
Steel screw fixings for timber/steel studwork ,anchors for masonry,
Section
n/a
Standard
BS EN 13162: 2001
SystemAccessories
n/a
SystemManufacturer
Sto Ltd
ThermalConductivityMaximum
0.036 W/mK
Pset_BuildingElementProxyCommon
Pset_CoveringCommon
Pset_WallCommon

More BIM objects

What's Changed?

8/13/2018

Object upgraded to NBS BIM Object Standard v2.0.