SIDERISE RH Open State Horizontal Cavity Barriers (formerly Lamatherm CW-RS)

Select regional version:

Download

The object content is configured for use in UK, but it may also be suitable for use in other locations.

Tags:

More Information:

SIDERISE RH cavity fire barriers for horizontal application in rainscreen cladding systems, suit air gaps up to 50mm in drained and ventilated facades and offer up to 120mins fire integrity. Tested to recent ASFP Guidance, these fire barriers comprise a non-combustible stone wool lamella core with reinforced aluminium foil faces. The exposed leading edge is also sealed with foil and encapsulated in a weather resistant black polymer film.

An intumescent strip bonded to the leading edge will expand rapidly to fully seal the gap between the barrier and the rear of the cladding in event of exposure to fire, to resist the passage of smoke and fire.

Their use ensures that the system will drain moisture within the façade construction, whilst maintaining airflow.

  • Horizontal application
  • Allows continuous ventilation/drainage behind cladding
  • Class A1
  • Up to 120mins fire integrity
  • Rapid seal closure times
  • Tested to ASFP BS EN 1363-1 & Principles of BS EN 1366-4
  • Air gaps up to 50mm
Platform Compatible Version Certified to
IFC IFC - 4 2.1
Revit Revit - 4 2.1

  • Properties and values
  • More information
  • More BIM objects
  • What's Changed?

Properties and values

COBie
BOS_General
NBS_Data
AirGaps
25mm
FireResistanceRating
90/30 integrity/ insulation to ASFP TGD 19 (prEN 1364-6),
Fixings
3 brackets per length
Sleeves
Green
SuitableForCavityWidth
27-425mm
ThermalRating
λ10 = 0.038 W/mK
ThirdPartyProductCertification
ewcl5 ME 5101 and Intertek WHI20-32944302 iss. 1
Pset_CoveringCommon

More information

  • NBS specification data
    Case studies and technical literature
  • More BIM objects

    What's Changed?

    10/19/2020

    Manufacturer revisions

    8/10/2018
    3/8/2017