Webertherm XM KM320 External Wall Insulation

Select regional version:

Download

The object content is configured for use in UK, but it may also be suitable for use in other locations.

Tags:

Render protected, mechanically fixed external wall insulation (EWI) system based on phenolic foam insulant with meshcloth reinforced basecoat, a top coat and a textured mineral finish.

Features and benefits:

  • Chlorofluorocarbon (CFC)/ hydrochlorofluorocarbon (HCFC) free.
  • Good impact resistance.
  • Provides weather protection.
  • Lightweight.
  • A wide range of finish coat colours are available.
  • Can be used for decorating and re-modelling existing facades.
  • BBA approved.
  • When installed to a masonry substrate and maintained in accordance with the manufacturers recommendations, the system will remain effective for at least 30 years. The durability can be extended to 60 years by using specific fixing accessories, additional adhesive and by following a planned inspection/maintenance schedule. Consult manufacturer for details.

Applications:

Suitable for use in buildings with a floor not exceeding 18 m above ground level for England and Wales, with a reduced height of 11 m for Scotland.

System components:

  • Weber fixings as specified for the substrate.
  • webertherm PHS insulation (of specified thickness).
  • weberend LAC (first layer, 3 mm).
  • weber standard meshcloth.
  • weberend LAC (second layer, 3 mm).
  • weberend PTC (6 mm thick).
  • weber PR310 primer.
  • weber mineral TF.

The installation must be capable of resisting all dead loads and design live loads, including impact and wind loads, and accommodate all thermal movements without damage.

System installation is to be strictly in accordance with Saint-Gobain Weber specification. Please note that any other manufacturer's products used within the system will invalidate the guarantee, and the performance cannot be supported.

Remedial work must be completed prior to the installation of Weber EWI Systems.

Recommendations:

  • The system should meet the building regulations requirements in compliance with BR 135. This includes achieving fire compartmentation of the structure using non-combustible fire barriers (webertherm MFL), installed vertically or horizontally at vulnerable areas such as window openings, doorways, penetrations and each floor level above the first floor level. The BR 135 recommends for each barrier to consist of a non-combustible material 100 mm minimum in height, which is fully bonded with weberend LAC and mechanically fixed using appropriate fire fixings through the meshcloth coat at maximum 400 mm centres. Additionally, install appropriate fire fixings (stainless steel as per BRE 135) at a rate of 1/m² minimum across the whole area receiving the above system.
  • Fixings must penetrate the structure in accordance with the fixing design to provide the appropriate pull out resistance. A survey of the building must be completed by an engineer to ensure the additional load does not have a detrimental effect on the building and the fixings are able to sufficiently penetrate the structure, to adequately support the Weber system. Weber will undertake fixing pull out tests and verify the adequacy of the fixing design based on a wind loading assessment carried out in accordance with BS EN 1991-1-4: 2005.
Platform Compatible Version Certified to
IFC IFC - 1 2.1
Revit Revit - 1 2.1

  • Properties and values
  • More BIM objects

Properties and values

COBie
BOS_General
NBS_Data
BeadsAndTrims
n/a
Considerations
Do not apply if frost is forecast within 24 hours of use, in damp/wet conditions, in temperatures below 5°C or above 30°C, on elevations in direct sunlight or where the substrate is hot
Constraints
The quality of application of these materials depends on suitable operative skills and product familiarity, restrictions on weather conditions during application and curing must be respected, sound trade practices and printed instructions must be followed, good access and appropriate protection must be provided
Density
15 kg/m³
FireBarriersAndStopsFixings
Stainless Steel
FireBarriersAndStopsMaterial
MFL
Fixing
Mechanical or mechanical and weberend LAC
HeavyDityMeshDimensions
5.5 x 5.5 mm
HeavyDutyRollSize
1m x 25m roll
HeavyDutyWeight
480 g/m²
InsulationAdditionalMechanicalFixings
n/a
InsulationAdhesive
weberend LAC
InsulationMaterial
PHS
Meshcloth
Balanced, open weave, alkaline resistant glass fibre meshcloth
MovementJointsAccessories
n/a
MovementJointsFormWith
n/a
MovementJointsSealant
n/a
Preparation
n/a
ProtectiveCoating
n/a
Reinforcement
Meshcloth
RenderApplication
n/a
RenderCarrierOrReinforcementFixings
n/a
RenderCarrierOrReinforcementMaterial
n/a
RenderCarrierOrReinforcementMeshSize
n/a
RenderColour
n/a
RenderDecorativeFinish
weberend PTC and dry dash
RenderMaterial
weberend LAC
SamplesRequired
n/a
StandardDutyMeshDimensions
3.5 x 3.5 mm
StandardDutyRollSize
1m x 50m roll
StandardDutyWeight
160 g/m²
SystemAccessories
n/a
SystemManufacturer
Saint-Gobain Weber
ThicknessRange
52-212mm
Uses
Facilitates the decoration and remodelling of existing, tired facades, simplifies wall construction within the new build sector