Rada Meynell 15/3 Thermostatic Mixing Valve

Select regional version:

Download

The object content is configured for use in UK, but it may also be suitable for use in other locations.

Tags:

1/2" point of use thermostatic mixing valve. Supplied complete with white plastic outer casing and integral check valves and strainers.

Platform Compatible Version Certified to
IFC IFC - 1 1.3
Revit Revit 2016 + 1 1.3

  • Properties and values
  • More information
  • More BIM objects

Properties and values

IFC
IfcExportAs
IfcValveType
IfcExportType
MIXING
COBie
NBS_General
NBS_Data
Arrangement
n/a
Capillary
n/a
CompressionForCopperTubes
n/a
CompressionForPlasticsPipes
n/a
ConnectionsInlet
15 mm compression
ConnectionsOutlet
15 mm compression
EnvironmentalProductDeclaration
n/a
FlangedForCastIron
n/a
FlangedForCopperAlloy
n/a
Operation
The Meynell 15/3 is designed to be installed into the supply pipework and must be used with a separate outlet flow control such as a tap
PressureManufacturerNote
Both hot and cold pressure should be nominally equal
PressureMaximumPressureLossRatio
10:1 (in favour of either supply)
PressureMaximumStatic
10.0 bar
PressureMinimum
0.1 bar
TemperatureControlMinimumBlendTemperatureDifferential
10°C
TemperatureControlTemperatureMaximum
42°C
TemperatureControlThermostaticControl
35°C to 45°C
TemperatureRangeColdWaterRange
1°C to 25°C
TemperatureRangeHotWaterRange
55°C to 65°C (recommended)
TemperatureRangeManufacturerNote
For safety reasons it is recommended that the hot water storage temperature is maintained at between 60°C to 65°C in ablutionary applications)
ThirdPartyCertification
Buildcert TMV3 Scheme Approved, WRAS Approved
ThreadedWherePressureTightJointsAreMadeOnTheThreads
n/a
ThreadedWherePressureTightJointsAreNotMadeOnTheThreads
n/a
WaterSupplyTemperatureMaximum
85°C
Pset_ValveTypeCommon
Pset_ValveTypeMixing

More information