Protan G PVC Single-Ply Roof Waterproofing Membrane

Select regional version:

Download

The object content is configured for use in UK, but it may also be suitable for use in other locations.

Tags:

Protan G PVC single-ply membranes are designed for installation in the Protan Green and Protan Protected systems in warm, cold and inverted roof constructions.

Protan G membranes are manufactured from pliable PVC with a glass fibre carrier. The PVC contains stabilisers, which make the membranes resistant to both high and low temperatures and UV-stable; and a fungicide for added protection against microbial attack.

The membranes are suitable for new-build and refurbishment projects on flat and pitched roofs, as well as forming details in exposed systems and fully adhered up-stands in the Protan Adhered System.

Protan G membranes are usually loose-laid, although they can be supplied with secret-fix strips factory-welded to the reverse side to allow for mechanical fixing.

Platform Compatible Version Certified to
AECOsim AECOsim - 1.0 -
ARCHICAD ARCHICAD - 1.0 -
IFC IFC 2X3 3 1.3
Revit Revit 2016 + 4 2.0
Vectorworks Vectorworks - 1.0 -

  • Properties and values
  • More information
  • More BIM objects
  • What's Changed?

Properties and values

IFC
IfcExportAs
IfcCoveringType
IfcExportType
MEMBRANE
COBie
NBS_General
NBS_Data
Accessories
n/a
Certification
BBA Certificate 00/3755, FLL Approval, IAB Certificate 06/0263, SINTEF NBI Approval 2007
ColourOptions
Dark grey (RAL7012), light grey (RAL7040)
DimensionStability
±0.1%
Elongation
≥200%
EnergyUse
n/a
Flatness
Length: +0.2%/-0%, Width: ±2%; Straightness: <30>
FleeceWeight
n/a
FoldabilityAtLowTemperatures
≤-30°C
GlassFibreCoreWeight
50 g/m²
HailResistance
≥17 m/s
IntegralBackingFleece
n/a
JointPeelResistance
n/a
JointShearResistance
≥450 N/50 mm
PolyesterWeight
n/a
PunctureResistance
≥600 mm
PVCWeight
1650 g/m²
RollLengthOptions
n/a
RollWeight
50 kg
RollWidthOptions
n/a
RootPenetrationResistance
Pass
StaticLoadResistance
≥20 kg
Straightness
<30>
TearResistance
≥110 N
TensileStrength
≥500 N/50 mm
ThicknessMinimum
1.5 mm
ThicknessOptions
1.5 mm, 1.8 mm
UVExposure
Pass
VisibleDefects
Pass
WaterTightness
Pass
WaterVapourResistance
n/a
WidthMinimum
2000 mm
Pset_CoveringCommon

More information

More BIM objects

What's Changed?

2/28/2017

Changes to reflect updates to the NBS BIM Object Standard v1.3

  • Removal of Uniclass2 property
  • Addition of Uniclass 2015 properties
  • Addition of COBie Category property value