NBS Source
I'm a manufacturer
Compare variants

LOFT54 Offset Single Glazed Panel Partition System (True)

Verified by manufacturer 9 days ago

IsoTec micro framed leaf in door frame, single leaf, single action.

Planet Variant:

Single glazed partition system with a 54 mm wide frame and with extruded LOFT transoms and/ or mullions.

Jump to:
+44 (0)1444 247933 Website

Application

All sectors: Commercial: Education; Healthcare; MOD; Airport & rail; Industrial; Hospitality; Residential & public.

Consult manufacturer for further details.

Description

Single glazed partition system with a 54 mm wide frame and with extruded LOFT transoms and/ or mullions.


Features and benefits:

  • The 54 mm-thick framework of the LOFT54 is the ideal foundation for industrial style banded glazing.
  • Delivers impressive acoustic performance in a range of styling options and installation methods.
  • The system can achieve a notable acoustic performance of up to 40 dB Rw uncompromised by its slender framework. For performance to up 46 dB Rw, see double-glazed formats (specified separately).
  • Available with IsoTec or IsoPro door leafs.
  • Also available as a bonded partition system (bonded LOFT transoms and/or mullions), or double-glazed in either bonded or 'true' formats. All to be specified separately.


Please note that acoustic, fire rated and structural certification and support for Planet products and systems is available on a project-specific basis. Please contact the specification team directly for further information.

General information

Color

Silver

Other

Finish

Polished

Anodized

Guidance for specification option:

Etched and anodized.

Powder-coated

Material

Aluminium

Guidance for specification option:

6063 T6.

Glass

Shape

-

Manufacturer guidance

To suit project requirements; consult manufacturer for further details.

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

-

Manufacturer guidance

Dealt with on a project specific basis as part of the O&M process; consult manufacturer for details.

Uniclass

Pr_25_71_57_60 Partition panelsPrimary
Ss_25_12_65_65 Panel partition systems

CAWS

K30/130 Relocatable partition system

K30/10 Relocatable partition system

Product range

LOFT / LOFT54

Specification data - Partition panels

Third-party certification

ISO 9001-UKAS (Quality); ISO 14001-UKAS (Environmental); Constructionline-Gold; Acclaim (SIPP); Achilles (Building confidence, SIPP); EPD - material accreditation & compliance; FIS Member; Considerate Construction; FORS Bronze; Build Profile.

Guidance for specification option:

EPD - material accreditation & compliance: Consult manufacturer for details (glass, PPC, aluminium, timber, ironmongery, waste, adhesive and more).

Unit size

-

Thickness

54 mm.

Partition height (nominal)

-

Manufacturer guidance

Insert requirements. For partitions over 3000 mm high, consult with manufacturer.

Width (nominal)

-

Manufacturer guidance

Insert requirements. For partitions over 1200 mm wide, consult with manufacturer.

Deflection allowance (maximum)

-

Head

No deflection; 27 mm deep x 54 mm wide channel.

No deflection; 50 mm deep x 54 mm wide channel.

±15 mm deflection; 80 mm deep x 74 mm wide channel.

±25 mm deflection; 90 mm deep x 74 mm wide channel.

Floor

-

Manufacturer guidance

Consult with manufacturer for system weight.

Verticals

27 mm deep x 54 mm wide channel.

50 mm deep x 54 mm wide channel.

Panel partition type

Framed glass - single offset glazed - with extruded LOFT transoms and/ or mullion profiles.

Framing, fixing points and joints

27 mm deep x 54 mm wide channel.

50 mm deep x 54 mm wide channel.

Manufacturer guidance

Mullions, transoms and corners: Extruded LOFT trims.

Solid panels

-

Type

Not required.

Back painted glass.

Steel faced boards.

Veneered panels.

Magnetic white board film.

Finish and colour

Not applicable.

To match frame.

Polyester powder-coated, RAL.

Guidance for specification option:

Insert colour requirement.

Polished and chemically brightened.

Linished and chemically brightened.

Etched and anodized.

Guidance for specification option:

Insert requirement.

Joint treatment

-

Type

Mullion, transom: 27 mm deep x 54 mm wide extruded profile; Corners: 54 x 54 mm corner box with abutment tracks.

Finish and colour

RAL.

Guidance for specification option:

Insert colour and gloss level.

Anodized.

Guidance for specification option:

Insert colour reference.

Glazed panels

-

Type

Single offset glazed, 12–15 mm annealed laminate.

Single offset glazed, 12–15 mm annealed acoustic laminate.

Single offset glazed, 12–15 mm toughened - heat soaked.

Single offset glazed, 12–15 mm LCD switchable.

Single offset glazed, 12–15 mm patterned, fluted.

Single offset glazed, 12–15 mm low iron.

Guidance for specification option:

All glass types available; consult manufacturer and insert requirements.

Integral blinds

n/a.

Guidance for specification option:

Not suitable for this system.

Additional features

None.

Double glazed/ boarded tech panel to incorporate room booking systems, access control and other electronics.

Door arrangement

-

Type

IsoTec micro framed leaf in door frame, single leaf, single action.

Door frames

Planet A188 aluminium door frame, with single leaf set.

Door panels

-

Type

Planet IsoTec 12 mm door leaf – non-acoustic.

Planet IsoTec 12 mm door leaf – 34 dB Rw.

Planet IsoPro, single glazed metal framed door leaf – 34 dB Rw.

Planet IsoPro, double glazed metal framed door leaf – 34 dB Rw.

Planet IsoPro, single glazed metal framed door leaf – 36 dB Rw.

Planet IsoPro, double glazed metal framed door leaf – 39 dB Rw.

Planet IsoPro, double glazed metal framed door leaf – 42 dB Rw.

Timber 44 mm leaf on hinges – 29 dB on to carpet.

Timber 44 mm leaf on hinges – 32 dB on to carpet.

Timber 54 mm rebated leaf on hinges – 33 dB on to carpet.

Timber 54 mm rebated leaf on hinges – 38 dB on to solid floor.

Timber 54 mm rebated leaf on hinges – 40 dB on to aluminium threshold.

Vision panels

Not required.

Required.

Guidance for specification option:

Available with timber door leaves only; consult manufacturer for details and insert requirements.

Ceiling

-

Type

-

Manufacturer guidance

Consult manufacturer for interface detail and insert requirements.

Method of support

-

Manufacturer guidance

Consult manufacturer for support detail and insert requirements.

Perimeters, skirtings, sills

27 mm deep x 54 mm wide channel.

Trims

Mullion, transom: 27 mm deep x 54 mm wide extruded profile.

Hardware

-

Manufacturer guidance

See appropriate door specification for applicable ironmongery options.

Seals

Clear perimeter compression seals.

Black perimeter compression seals.

Cable management and outlets

Not required.

As Glazed panels - Additional features.

Guidance for specification option:

Double glazed/ boarded Tech Panel to incorporate room booking systems, access control and other electronics.

Other features

-

Manufacturer guidance

Consult manufacturer and insert requirements or leave blank.

Product Reference

LOFT54 Offset Single Glazed Panel Partition System (True)

Manifestation

Allowance of 2 nr rows 50 mm dots or square (minimum) Opal Frost.

Guidance for specification option:

Insert requirements.

Artwork and custom manifestation to client design.

Guidance for specification option:

Insert requirements.

Manufacturer guidance

To architects choice and in accordance with the requirements of Approved Document K.

StrengthGrade

-

Manufacturer guidance

Consult with the manufacturer to ensure the system complies with current regulations BS 5234:1992 non load-bearing screens not protecting a change in adjacent floor level of >380 mm.


For glass load resistance criteria;

  • BS 5234 not applied to “all glass partition screens”.
  • Nominal line load criteria of “short-term impact load” utilised.
  • 0.36 kN/m applied as linear load at 1100 mm above FFL.
  • Glass deflection limited to L/65 or 25 mm, whichever is less under load.
  • Maximum deflection and stress in accordance with the glass performance requirements of EN 572/ EN 12150/ EN 12543/ EN 14179 (where heat soaked).


Building regulations Part N (BS 6262 & BS EN 12600) + InsStucEng publication “structural use of glass in buildings” insert as required:

  • 0.36 kN/m (default load).
  • 0.74 kN/m.
  • 1.5 kN/m.


BS 6180:2011 barriers in and about buildings for Atria or protected change in adjacent floor level of >380 mm.

Horizontal uniformly distributed line load 1100 mm above FFL (glass deflection limited to L/65 or 25 mm, whichever is less relative to glass fixings).

Structural glass based on line-load and attendant UDL + point load, insert as required:

  • 0.74 kN/m.
  • 1.5 kN/m.
  • 3.0 kN/m.

Acoustic performance

35 dB Rw.

36 dB Rw.

37 dB Rw.

38 dB Rw.

39 dB Rw.

Show more

Manufacturer guidance

To comply to EN ISO 10140-2 and ISO 717-1: Acoustics vary according to framework/glazing options subject to further design development.

Partition

Framed glass - single offset glazed - with extruded LOFT transoms and/or mullions.

Fasteners

To manufacturer's specification, type, length and frequency to suit substrates.

Joint treatment

27 mm deep x 54 mm wide extruded LOFT mullion and/ or transom.

System accessories

-

Manufacturer guidance

Tech panels, access control - consult with manufacturer for details.

Samples required

-

Manufacturer guidance

Consult with manufacturer.

Finish/ Colour

Polyester powder-coated, RAL.

Guidance for specification option:

Insert colour requirement.

Polished and chemically brightened.

Linished and chemically brightened.

Etched and anodized.

Guidance for specification option:

Insert requirement.

Sustainability data

Contains Red List materials

No

Guidance for specification option:

No substance on the “Candidate List of Substances of Very High Concern for authorisation” derived under REACH is present either above the limits for registration with the European Chemicals Agency or in excess of 1 weight–% of the product.

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

71.2 kg CO₂ eq/m²

Guidance for specification option:

There will be slight variances in embodied carbon if different glass thicknesses, etc, are used. These embodied carbon figures are for 1 m2 of each type of partition – modules A1-A3 including biogenic carbon.


The EPD for the single glazed partition systems is based on powder-coated aluminium-framed single-glazed partition systems using 12.8mm laminated glass, without a door.

Recyclability

100%

Guidance for specification option:

Aluminium and glass.

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

-

Manufacturer guidance

17–28% for glass.

70% for aluminium..

BIM objects

Platform Compatible Version
Revit
-

1

Literature

Planet Partitioning Product Guide

Planet Partitioning Product Guide

LOFT54 - Images & Information

LOFT54 - Images & Information

Case studies

Fora, Reading

Fora, Reading

Similar products from Planet

FireClear100 Double  Glazed Partition System

FireClear100 Double Glazed Partition System

FireClear20  Single Glazed Partition System

FireClear20 Single Glazed Partition System

FireClear54 Double Glazed Partition System

FireClear54 Double Glazed Partition System

FireEco Ei30 Double Glazed Partition System

FireEco Ei30 Double Glazed Partition System

FireEco Ei30 Single Glazed Partition System

FireEco Ei30 Single Glazed Partition System

FireEco Ei60 Double Glazed Partition System

FireEco Ei60 Double Glazed Partition System

FireEco Ei60 Single Glazed Partition System

FireEco Ei60 Single Glazed Partition System

FirePro E120 Single Glazed Partition System And Ei 60 Doorset

FirePro E120 Single Glazed Partition System And Ei 60 Doorset

FirePro E30 Double Glazed Partition System And Doorset

FirePro E30 Double Glazed Partition System And Doorset

FirePro E30 Single Glazed Partition System and Doorset

FirePro E30 Single Glazed Partition System and Doorset