Net2 Plus 12V 2A PSU, Plastic

Select regional version:

Download

The object content is configured for use in UK, but it may also be suitable for use in other locations.

Tags:

Net2 plus is a single door access control unit and is the most advanced control unit in the Paxton Net2 ACU range.

Net2 plus has on-board TCP/IP to allow direct connection to a computer network, this can save time, money and result in a better, more resilient system.

Net2 plus control units can also be connected together using a dedicated RS485 network.This reduces the number of TCP/IP network points required for larger systems.

Hardware features include:

  • Volt free control relay x 2
  • Input for PSU fail
  • Input for tamper
  • Alarm output
  • Dedicated intruder alarm input

See data sheet: http://www.paxton.co.uk/docs/DataSheets/DS1038.pdf

The 12V 2A Power supply unit is available in either a plastic or metal cabinet. The cabinet can house both the 12V 2A PSU and a Net2 and the option to accommodate a 12V/7Ah back up battery if desired. A tamper switch is also installed which registers an alarm if the lid is opened when connected to an ACU.

Platform Compatible Version Certified to
IFC IFC 2X3 4 1.3
Revit Revit 2016 + 5 2.0

  • Properties and values
  • More BIM objects
  • What's Changed?

Properties and values

IFC
IfcExportAs
IfcControllerType
IfcExportType
PROPORTIONAL
COBie
NBS_General
NBS_Data
Accessories
Net2 Plus 1 door controller, Net2 Plus 1 door controller - 12 V 2A PSU plastic cabinet, Net2 Plus 1 door controller - PoE+ plastic cabinet, Net2 Plus 1 door controller plastic housing, Net2 Plus 1 door controller - 12V 2A PSU metal cabinet, Net2 Plus 1 door controller - PoE+ metal cabinet
Application
Single door access control unit
CableType
n/a
Communication
TCP/IP, RS485, DHCP support, Ethernet network speed 100 Mbit/s auto MDIX, Ethernet bandwidth requirement 200 kbits/sec
ConcealedInstallation
n/a
Containment
n/a
ContainmentAccessories
n/a
Controls
n/a
ControlSoftware
n/a
DataRetention
30 days
DoorOpeningTime
1 sec - 999,999 secs
DoorStatusMonitoring
n/a
EquipmentInterconnectivity
n/a
Hardware
2 reader ports per ACU, 4 readers/keypads per ACU, 500mA total ACU reader port output current, 3rd party reader support, Belden 9540 reader cable, CAT5 or Belden 8723 network cable
InstallationInstructions
www.paxton.co.uk/​docs/​Instructions/​ins-20006.pdf
LockingMechanisms
n/a
MaximumUsers
50000
MethodOfAuthorization
n/a
MoistureResistance
False
Mounting
On wall
NumberOfAccessLevels
250
OperatingTemperature
0°C - +55°C
PINLength
99
Readers
Proximity, magstripe or keypads
Registration
n/a
RewireableInstallation
n/a
StoredEvents
2500+
SystemAccessories
n/a
SystemSupplier
n/a
SystemType
PC based system
VandalResistance
Low
Pset_ControllerTypeCommon
Pset_ElectricalDeviceCommon

More BIM objects