High performance expanded polystyrene insulation intended for use above the waterproof membrane on inverted roofs.

Platform Compatible Version Certified to
IFC IFC 2X3 2 1.3
Revit Revit 2016 + 4 2.0

  • Properties and values
  • More information
  • More BIM objects
  • What's Changed?

Properties and values

COBie
NBS_General
NBS_Data
BendingStrength
250 kPa
CalorificValue
40 MJ/kg
Certification
BBA certificate 01/3812
CoefficientOfLinearExpansion
0.6 x 10^-6/°C
CompressiveStrengthMinimum
200 kN/m² (10% deformation), 90 kN/m² (1% nominal strain)
DimensionalStability
DS(N)5 (±0.5%)
Edges
15 mm shiplap
FaceSize
1200 x 1200 mm
Facing
n/a
Form
Board
GradeOptions
EPS 200, EPS 300
MassDensity
30 kg/m³
MaterialIncompatibility
Protect from hydrocarbons, strong solvents, and PVC-sheathed cables
RecycledContent
n/a
SpecificHeatCapacity
n/a
TemperatureRange
-150 to +80°C
ThermalConductivity
0.033 W/mK
ThermalIrEmissivityBack
n/a
ThermalIrEmissivityFront
n/a
ThermalResistance
7.27 m²K/W
ThicknessOptions
50-250 mm, in 5 mm increments
Tolerances
n/a
WaterVapourDiffusionResistanceFactor
<>
Pset_CoveringCommon

More information

  • NBS specification data
  • More BIM objects

    What's Changed?

    2/28/2017

    Changes to reflect updates to the NBS BIM Object Standard v1.3

    • Removal of Uniclass2 property
    • Addition of Uniclass 2015 properties
    • Addition of COBie Category property value

    Objects have also been updated to Revit 2015