Flowcoat TL is a high performance, solvent free, chemical resistant, two-component coloured epoxy resin coating. It is for use in demanding surfaces such as those required in dry processes in the light engineering and pharmaceutical industries, for corridors, locker rooms, culverts and warehousing, etc.

Surface preparation:

All loose substrate material, laitance and contamination to be carefully removed. The surface must be prepared by grinding, vacuum-blasting, carborundum grinding, diamond grinding or machine sanding with coarse sandpaper to achieve minimum surface tensile strength of 1.5 Mpa. Substrate to be carefully vacuum-cleaned after treatment. The substrate must not be washed after treatment.

Platform Compatible Version Certified to
IFC IFC - 1 1.3
Revit Revit 2016 + 2 2.0

  • Properties and values
  • More information
  • More BIM objects
  • What's Changed?

Properties and values

IFC
IfcExportAs
IfcCoveringType
IfcExportType
FLOORING
COBie
NBS_General
NBS_Data
Application
n/a
BarcolHardness
n/a
BondStrength
>2.5 N/mm²
Certification
CE Marked
CoefficientOfThermalExpansion
n/a
ColourOptions
Goosewing Grey 222, Mid Grey 280, Yellow Grey 217, Beige 326, Emerald Green 740, Tile Red 637, Sky Blue 452, Yellow 340
CompressiveStrength
>80 N/mm²
CureTime
Light traffic: 15 hours, full traffic: 2 days, full chemical cure: 5-7 days
Density
n/a
ElongationAtBreak
n/a
FinishOptions
gloss
FlexuralStrength
>60 N/mm²
Grout
n/a
ImpactResistance
6 Nm
LevellingScreed
If required
Membrane
n/a
ModulusOfElasticity
n/a
MovementJointsAttachment
n/a
MovementJointsType
n/a
Primer
Flowprime (required for weak substrates)
Reinforcement
n/a
ResinFlooring
Flowcoat TL (FeRFA Type 3)
ResinSkirtingsAndUpstands
n/a
SlipResistance
Dry >40 low slip potential
SubstratePreparation
Shot blasted
SubstrateTesting
Moisture content of substrates dry to 75% RH
SurfaceHardness
180 secs. Koenig hardness test
SurfaceTreatment
Optional anti-slip coating
SystemAccessories
n/a
TemperatureResistance
<>
TensileStrength
>15 N/mm²
ThermalConductivity
n/a
ThicknessOptions
0.35 mm
Toxicity
n/a
Uses
Dry environments in the light engineering and pharmaceutical industries, locker rooms, culverts, and warehousing
VapourPermeability
n/a
WaterPermeability
0.001 kg/m² x h^(0.5), Nil- Karsten test (impermeable)
WearResistance
Abrasion quantity <0.1 cm³,=""><200 mg="" loss="" (abrasion)="" to="" en="" iso="">