Verified by manufacturer over a year ago
European Technical Approvals
Certificate type
QA Certificate
Certificate type
Embedded conduit inlet system designed to work in combination with CSD’s SLIPSIL plug System.
Mainly used to provide a water and gas tight seal for single Cables and pipes, but Trefoil cable range can be used with this system.
SLIPSIL® embedded conduit inlet system is designed to go hand in hand with the CSD’S SLIPSIL sealing plugs range providing a total water & Gas tight seal. Embedded Conduit System is designed to enables the SLIPSIL range to be installed easily preventing any damage to the plugs during insertion and ensuring the plugs is not inserted too deep into the conduit opening.
SLIPSIL Sealing plugs can also be used for core drilled holes. The tolerances of the drilled hole should be within the tolerances of the plug series. Single plug can be installed on one side of the conduit only if required to providing water & Gas tight seal. However, for optimum sealing performance it is advisable that plugs are inserted each side of the conduit. Care should be taken that the ducted cable/pipe is not passed through the conduit opening at an angle. For horizontal ducts, it is extremely important to support the pipes properly at both sides of the conduit.
Features and benefits:
Color | Orange |
Material | Plastic |
Uniclass | |
CAWS | P12/35 Flexible intumescent gap sealer P12/330 Flexible intumescent gap sealer |
Size | CSD 40 CI.Guidance for specification option: Cable/ pipe outer diameter: 5-22 mm. CSD 50 CI.Guidance for specification option: Cable/ pipe outer diameter: 6-32 mm. CSD 60 CI.Guidance for specification option: Cable/ pipe outer diameter: 14-40 mm. CSD 70 CI.Guidance for specification option: Cable/ pipe outer diameter: 22-50 mm. CSD 80 CI.Guidance for specification option: Cable/ pipe outer diameter: 28-60 mm. CSD 100 CI.Guidance for specification option: Cable/ pipe outer diameter: 40-75 mm. CSD 125 CI.Guidance for specification option: Cable/ pipe outer diameter: 60-92 mm. CSD 160 CI.Guidance for specification option: Cable/ pipe outer diameter: 88-125 mm. CSD 200 CI.Guidance for specification option: Cable/ pipe outer diameter: 110-160 mm. Manufacturer guidanceInlet conduit. |
Accessories | Adjustment pipe. Connector. Fixation. |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |