Verified by manufacturer 29 days ago
Alcumus SafeContractor
Certificate type
Constructionline
Certificate type
ISO 9001 Quality Management
Certificate type
dhf certificate
Certificate type
Thermally insulating and sound reducing roller shutter.
Suitable for loading bays, factories, warehouses, boiler or turbine halls; television or recording studios, and any applications where security is required together with thermal insulation, strength and robust design.
This door system is perfectly suited for loading bays, factories, warehouses, and any applications where either security, acoustic performance, thermal insulation, or a combination of these factors is a requirement.
These Insulated Rolling Shutters doors have been used extensively on projects both in the UK and worldwide where their integral strength and robust design assures continued reliability of operation and optimum design life.
Features and benefits:
Operation options:
Tubular Motor
Direct Drive Motor
Manual overrides are supplied for use in the event of power failure.
Maximum sizes:
(Please contact our sales team to discuss if there is a requirement beyond these dimensions).
Color | Beige Black Blue Bronze Brown |
Finish | Galvanized Powder-coated |
Material | Steel Guidance for specification option: Carbon steel. |
Shape | Square Rectangle |
Width | Bespoke Guidance for specification option: These doors are bespoke, manufactured to suit the project requirements subject to the following maximum sizes: - Tubular Motor option: 6000mm wide x 3000mm high Direct Drive Motor option: 10000mm wide x 10000mm high |
Height | Bespoke Guidance for specification option: These doors are bespoke, manufactured to suit the project requirements subject to the following maximum sizes: - Tubular Motor option: 6000mm wide x 3000mm high Direct Drive Motor option: 10000mm wide x 10000mm high |
Warranty description | One year |
Uniclass | |
CAWS | L20/610 Roller shutters/ curtains |
Product range |
Standard | To BS EN ISO 10140-2:2010.Guidance for specification option: Measurements of Airborne Sound Insulation.
|
Opening sizes | Insert requirements.Guidance for specification option: Available up to 10 x 10 m as standard (clear width x clear height), significantly greater sizes available. |
Format | Thermally insulating and sound reducing. |
Arrangement | Vertical, face-fitted across opening.Vertical, fitted into reveal. |
Performance | |
Resistance to wind load | To BS EN 12424, class 5. |
Acoustic performance | 18 dB Rw. |
Thermal resistance | 1.1 W/m²K.Guidance for specification option: (3.2 W/m²K at quirks). |
Shutter curtain. | |
Lath material | Galvanized steel.Guidance for specification option: The shutter curtain is constructed using continuously interlocked 95 mm deep galvanized steel foam bonded insulated laths secured by end locks. |
Profile | 95 mm flat.Guidance for specification option: 95 mm deep. |
Finish and colour | Galvanized.Guidance for specification option: Standard. Polyester powder coated.Guidance for specification option: Insert requirement. |
Frame and guides | |
Material | Carbon steel. |
Finish | Galvanized.Guidance for specification option: Standard. Polyester powder-coated. |
Colour | Choice of RAL/ plastisol colours.Guidance for specification option: Insert RAL colour requirement, or type 'Not applicable' for Galvanized. |
Operation | |
Mode | Automatic.Guidance for specification option: Electrical via a 400 V nominal, three-phase, direct drive geared motor with integrated safety brake. |
Control | Low level control panel.Guidance for specification option: Low level control panel with constant pressure open/ close/ stop push-buttons mounted adjacent to the shutter. |
Hardware | Control Panel with open/ close/ stop push buttons. |
Accessories | Not required.Building management system (BMS) linkage.Card reader.Double-glazed vision panels.Light curtain.Photocells.Radar.Status indicator.Timer delay closure. |
Weight | 45 kg/m². Guidance for specification option: Approximately. |
Motor | Tubular motor. Guidance for specification option:
Direct drive motor. Guidance for specification option:
|
Size: | Bespoke. Guidance for specification option: Bespoke; consult manufacturer for details and insert requirements. Maximum sizes:
Please discuss with Bolton gate sales team if there is a requirement beyond these sizes. Manufacturer guidanceManufactured to suit Client opening sizes. |
End plates | Prime painted mild steel. Guidance for specification option: Thickness to suit the respective opening size and provided with angles for fixing to the structure. |
Rail | Extruded aluminium bottom rail. Guidance for specification option: Provided with a rubber weatherstrip. Manufacturer guidanceBottom rail. |
Casing | Galvanized steel coil. Guidance for specification option: Casing and motor casing are provided as standard to close off the operating mechanism and complete the aesthetic appearance of the door. On the tubular motor system, the casing is a more compact chamfered design. |
Frame/ Guides | Vertical guides, galvanized steel. Guidance for specification option: Vertical guides are formed from rolled galvanized steel in a double rebate profile and fitted with twin brush strips. Full height angles are provided for mounting to the structure. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Recyclability | 95% |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 0 % |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |