Add to bundle (63)An addressable Waterproof Manual Call Point that has been designed for use on an Apollo Addressable system.
An addressable Waterproof Manual Call Point that has been designed for use on an Apollo Addressable system.
A Visual Alarm Device (VAD) with an EN54-23 category of C-3-15. It can be mounted using the Apollo first fix base. The VAD uses a high intensity LED to produce a white flash colour.
A Visual Alarm Device (VAD) with an EN54-23 category of C-3-8.5. It can be mounted using the Apollo first fix base. The VAD uses a high intensity LED to produce a white flash colour.
A Visual Alarm Device (VAD) with an EN54-23 category of W-2.5-7. It can be mounted using the Apollo first fix base. The VAD uses a high intensity LED to produce a white flash colour.
Dual Isolator provides two independent isolators which sense and isolate short circuits on Discovery/XP95 loops and spurs. DIN-Rail enclosure capable of clipping to a standard 35mm DIN-Rail.
A loop powered Input/Output Unit providing a voltage-free relay output and a single monitored switch input. DIN-Rail enclosure capable of clipping to a standard 35mm DIN-Rail.
DIN-Rail Interface Enclosures are available in two sizes and can be used for housing intrinsically safe (IS) barriers or DIN-Rail mounted interfaces.
Mains Switching Input/Output unit provides voltage-free, single pole change-over relay output and a monitored switch input. DIN-Rail enclosure capable of clipping to a standard 35mm DIN-Rail.
A loop powered Output Unit providing a voltage-free relay output. Capable of switching up to 30V at 1A. DIN-Rail enclosure capable of clipping to a standard 35mm DIN-Rail.
Sounder Controller designed to control a zone of externally powered sounders and report the status to the control panel. DIN-Rail enclosure capable of clipping to a standard 35mm DIN-Rail.
Switch Monitor designed to monitor the state of one or more single pole, volt-free contacts. DIN-Rail enclosure capable of clipping to a standard 35mm DIN-Rail.
Switch Monitor Plus monitoring the state of one or more single pole, volt-free contacts. Output for resetting a remote detector. DIN-Rail enclosure capable of clipping to a standard 35mm DIN-Rail.
Zone Monitor powers and controls the operation of a zone of up to 20 Apollo Series 65 or Orbis detectors from a Discovery/XP95 loop. DIN-Rail enclosure capable of clipping to a standard 35mm DIN-Rail.
Intelligent analogue addressable Carbon Monoxide Detector with 5 sensitivity mode settings and suitable as a secondary detector which responds well to deep seated fires.
Intelligent analogue addressable CO-heat Multisensor with 5 sensitivity mode settings and responds well to both flaming and deep seated fires.
Intelligent analogue addressable Heat Detector with 5 sensitivity mode settings for various rate of rise and static temperature thresholds.
Intelligent analogue addressable Ionisation Detector with 5 sensitivity mode settings and responds well to fast burning flaming fires.
Intelligent analogue addressable multisensor detector with 5 sensitivity mode settings and responds well to both smouldering and flaming fires.
An Open-Area Sounder Visual Indicator designed for Apollo's addressable Discovery protocol. The product includes 15 tone pairs which can be used for other purposes in addition to warning of fire.
An Open-Area Voice Sounder designed for Apollo's addressable Discovery protocol. The product includes 4 pre-set message pairs, capable of up to 15 tone message pairs.
An Open-Area Voice Sounder Visual Indicator designed for Apollo's addressable Discovery protocol. The product includes 4 pre-set message pairs, capable of up to 15 tone message pairs.
Intelligent analogue addressable smoke detector with 5 sensitivity mode settings and responds well to smouldering fires.
An addressable loop powered Input/Output Unit providing a voltage-free relay output and a single monitored switch input. Capable of switching up to 30V at 1A.
The Apollo Based Mounted Dual IR/UV Flame Detector has been designed to offer the protection of a visual flame detector that is compatible with all XP95 and Discovery Bases.
The Apollo Based Mounted IR3 Flame Detector has been designed to offer the protection of a visual flame detector that is compatible with all XP95 and Discovery Bases.
The Apollo Based Mounted UV Flame Detector has been designed to offer the protection of a visual flame detector that is compatible with all XP95 and Discovery Bases.
Intelligent Flame Detector designed for Apollo's Addressable Protocol. Is ideal for covering areas where a flaming fire may occur.
Intelligent Flame Detector designed for Apollo's Addressable Protocol. This product has been designed to work in a number of different hazardous environments.
An Intelligent Manual Call Point that is fully compatible with XP95, Discovery and CoreProtocol panels. This Manual Call Point includes an short circuit isolator.
An Open-Area Sounder designed for Apollo's digital communication protocols, Discovery and XP95. The product includes two volume settings and has an IP65 rating.
An Open-Area Sounder Visual Indicator designed for Apollo's digital communication protocols, Discovery and XP95. The product includes two volume settings and has an IP65 rating.
An Open-Area Visual Indicator designed for Apollo's digital communication protocols, Discovery and XP95. The product includes two volume settings and individual or group addressing.
An addressable Locally Powered Zone Monitor powers and controls the operation of a zone of up to 40 Orbis or Series 65 detectors.
The Loop-Powered Visual Indicator is a local-area visual indicator designed for indoor use.
The Loop-Powered Visual Indicator is a local-area visual indicator designed for indoor use.
Your query has been sent.
A technical consultant from will be in touch soon.
Manufacturers using NBS National BIM Library adhere to our code of conduct.
OmniClass
The creation of BIM objects for the inclusion on the National BIM Library includes Omniclass classification codes and titles.
Copyright © 2014 the secretariat for the OmniClass Development Committee. All Rights Reserved. http://www.omniclass.org/