Thermal Windpost TWP2

Select regional version:

Download

The object content is configured for use in UK, but it may also be suitable for use in other locations.

Tags:

The revolutionary Ancon Thermal Windpost (TWP2) is designed to span vertically between floors, to provide additional lateral support for panels of masonry. It has been specially designed and engineered after extensive research and testing, with a variety of features to improve the thermal performance and repeatability of the junction. 

With robust integral non-combustible mineral fibre insulation in combination with a thermal slot array, using the Thermal Windpost in place of a traditional windpost results in up to 70% reduction in thermal transmission through the span of the section, as well as  improving the consistency and repeatability of fitting insulation in and around the post, ensuring that the intended thermal design is met.

Although it holds the same strong performance, the patented Thermal Windpost is engineered to be up to 35% lighter than traditional windposts, making it much easier to handle on site. The teardrop hem increases the strength of the post and eliminates sharp edges, meaning that safety on site is also improved.

Ancon Thermal Windposts are designed to add thermally efficient lateral support to cavity walls where either wind loads are high, or the span between primary structural members is large. The hemmed leg of the windpost is built into the blockwork, and the blockwork tied through the leg of the windpost to minimise any possible movement or cracking of internal finishes. If a vertical movement joint is required in place of a tied joint, ties with a debonding sleeve on one side can be supplied.

 

Platform Compatible Version Certified to
IFC IFC - 1 2.1
Revit Revit - 1 2.1

  • Properties and values
  • More BIM objects

Properties and values

IFC
IfcExportAs
IfcBuildingElementProxyType
IfcExportType
USERDEFINED
COBie
BOS_General
NBS_Data
Accessories
Ancon SDN ties to connect the outer leaf, Ancon SNS wall ties used across the post in the inner blockwork
ConfigurationType
Built into inner masonry leaf
DepthRange
165 - 240 mm
HeadAndBaseFixings
Concrete, steel, timber or other
HeightRange
165 - 275 mm
IntegralCavityTieLengthOptions
Min. 75 mm in 25 mm increments (SDN or SPN outer leaf tie), min. 210 mm (SNS inner leaf tie)
IntegralCavityTiesDesignEmbedmentLength
50
IntegralCavityTiesEndTypes
Outer leaf tie asymmetrical sliding tee slot end with deformed plate embedment end, inner leaf tie symmetrical deformed plate embedment ends
IntegralCavityTiesLength
Min. 62.5 mm (SDN or SPN outer leaf tie) & min. 100 mm (SNS inner leaf tie)
IntegralCavityTiesMortarJointThickness
10
IntegralCavityTiesMovement
Tolerant
IntegralCavityTiesResistanceToWaterCrossingCavity
Resistant
LengthRange
2000 - 4000 mm
MaximumDeflection
Span/360
ProfileSize
Type A
Section
Length to suit construction
SizesSectionAngle
TWP2-[Height]-[A]
SizesSectionChannel
0
SizesSectionFlatPlate
0
SizesSpan
2000-4000 mm
WidthRange
Varies