B35T - Plate heat exchanger

Select regional version:

Download

The object content is configured for use in UK, but it may also be suitable for use in other locations.

Tags:

The B35T is a perfect fit for a large number of applications within district heating, heat recovery for industry and HVAC, combined heat & power as well as engine oil cooling.

It’s the natural choice for efficient heat transfer at low pressure drop, in systems with up to 2½” piping and 50 m3/h water flow.

For lower capacities it is available with smaller ports matching 2” connections on primary side only, or on both sides.

The B35T is capable of handling a water flow rate up to 50 m3/h.

Platform Compatible Version Certified to
IFC IFC 2X3 2 1.3
Revit Revit 2016 + 3 2.0

  • Properties and values
  • More BIM objects
  • What's Changed?

Properties and values

COBie
NBS_General
NBS_Data
BPHEWeight
74.86
ConnectionsCentresDistanceHorizontal
159
ConnectionsCentresDistanceVertical
309
ConnectionsLength
27.1
ConnectionsLengthOptions
27.1 mm, 54.2 mm
CornerRadius
35
InnerCircuitMaximumWorkingPressureAtTestTemperature1
2600000
InnerCircuitMaximumWorkingPressureAtTestTemperature2
2200000
InnerCircuitTestPressure
4000000.01
InternationalContactInformation
www.swep.net/​en/​contact/​Pages/​default.aspx
LeadingPlateThickness
4
MaterialBrazing
Pure Copper
MaterialGaskets
n/a
MaterialStandardConnection
Stainless steel, 1.4401
MaterialStandardPlates
Stainless steel, 1.4401
MaximumNumberOfPlates
260
MaximumTemperature
225
MinimumTemperature
-196
Output
To determine Output please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
PortSize
61
PortSizes
61/42
PrimaryMediumFlowRate
To determine PrimaryMediumFlowRate please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
PrimaryMediumFluid
To determine PrimaryMediumFluid please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
PrimaryMediumInletTemperature
To determine PrimaryMediumInletTemperature please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
PrimaryMediumOutletTemperature
To determine PrimaryMediumOutletTemperature please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
PrimaryMediumPressureLoss
To determine PrimaryMediumPressureLoss please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
PrimaryMediumWorkingPressure
To determine PrimaryMediumWorkingPressure please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
SecondaryCircuitMaximumWorkingPressureAtTestTemperature1
2600000
SecondaryCircuitMaximumWorkingPressureAtTestTemperature2
2200000
SecondaryCircuitTestPressure
4000000.01
SecondaryMediumFlowRate
To determine SecondaryMediumFlowRate please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
SecondaryMediumFluid
To determine SecondaryMediumFluid please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
SecondaryMediumInletTemperature
To determine SecondaryMediumInletTemperature please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
SecondaryMediumOutletTemperature
To determine SecondaryMediumOutletTemperature please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
SecondaryMediumPressureLoss
To determine SecondaryMediumPressureLoss please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
SecondaryMediumWorkingPressure
To determine SecondaryMediumWorkingPressure please visit the web link recorded against either SSPCalculationSoftware or InternationalContactInformation. Please replace this text once the value has been defined using specification / selection software SSPG7.
SSPCalculationSoftware
www.swep.net/​en/​products_​solutions/​ssp_​calculation_​software/​Pages/​default.aspx
TestTemperature1
408.15
TestTemperature2
498.15
TotalThicknessOfPlates
620
Pset_HeatExchangerTypeCommon
Pset_HeatExchangerTypePlate

More BIM objects

What's Changed?

1/19/2017

Changes to reflect updates to the NBS BIM Object Standard v1.3

  • Removal of Uniclass2 property
  • Addition of Uniclass 2015 properties
  • Addition of COBie Category property value

Objects have also been updated to Revit 2015