Radbar Amber 2 Foil

Select regional version:

Download

The object content is configured for use in UK, but it may also be suitable for use in other locations.

Tags:

Radbar Amber 2 Foil Barrier protects buildings, properties and occupants from the ingress of radon, carbon dioxide and methane gases. It has been independently tested to ISO 15105-1 and complies fully to BS 8485:2015, making this high quality membrane suitable for use on NHBC Amber 2 sites. Sites that may require Radbar Amber 2 Foil Barrier include former coalfields, contaminated industrial sites, landfill and brown field sites.

Radbar Amber 2 Foil Barrier is manufactured from high quality reinforced polythene with an aluminium core, it complies with the latest codes of practice as published by the BRE and CIRIA.

Radbar Amber 2 Foil Barrier is supplied in rolls 2m wide x 50m long. A full range of accessories are available to suit Amber 2 installations including joining tapes, top hats and pre-formed corners.

For a complete system that complies to BS 8485:2015 use Amber 2 Foil Barrier in conjunction with Radbar Gas Resistant DPC or Radbar Hydrocarbon DPC.

Platform Compatible Version Certified to
IFC IFC 2X3 1 2.0
Revit Revit 2016 + 1 2.0

  • Properties and values
  • More BIM objects

Properties and values

COBie
BOS_General
NBS_Data
CarbonDioxidePermeabilityCoefficient
2.58 x 10-19 m² Pa -1 s-1
Compatibility
Suitable for use with adjoining gas resistant dpms
DurabilityOfWatertightnessAgainstAgeing
To BS EN 1296, BS EN 13967, BS EN 1928
Elongation
0.3
MethanePermeability
0.09 ml/day·m²·atm
MethanePermeabilityCoefficient
1.56 x 10-19 m² Pa -1 s-2
PunctureResistance
1.29 kN
RadonPermeability
8 x 10-15 m² s-1
ResistanceToStaticLoading
20 kg
ResistanceToTearing
400 N
ResistanceToWaterPenetration
To BS EN 13967, BS EN 1928
TensileStrength
700 N/50 mm
ThirdPartyCertification
BBA Agrément Certificate 17/5387, CIRIA
TransmissionRateOfVolatileLiquidsDiesil
0.246 g/m²/h
TransmissionRateOfVolatileLiquidsPetrol
0.135 g/m²/h
TransmissionRateOfVolatileLiquidsToluene
0.583 g/m²/h
TransmissionRateOfVolatileLiquidsXylene
0.571 g/m²/h
WaterColumnTest
>300
Pset_CoveringCommon

More BIM objects