Rada V10 Contract Pack

Select regional version:

Download

The object content is configured for use in UK, but it may also be suitable for use in other locations.

Tags:

TMV2 approved exposed, single sequential thermostatic shower valve suitable for commercial and semi-domestic applications, supplied with VR145 vandal resistant shower head and rigid riser.

Platform Compatible Version Certified to
IFC IFC - 1 1.3
Revit Revit 2016 + 1 1.3

  • Properties and values
  • More information
  • More BIM objects

Properties and values

IFC
IfcExportAs
IfcValveType
IfcExportType
MIXING
COBie
NBS_General
NBS_Data
ConnectionInlet
15 mm Compression
ConnectionOutlet
½201D BSP Flat Face / 15 mm Compression
ConnectionStandard
Hot: Left, Cold: Right, Outlet: top
FlowRateManufacturerNote
At supply pressures > 0.5 bar, we recommend fitting the 9 L/min flow regulator. For increased water saving the 6 L/min flow regulator should be fitted (both supplied)
FlowRateMaximum
30 L/min (achieved at 1.0 bar pressure loss across the valve with flow regulators removed)
FlowRateMimimum
The minimum flow rate to achieve a full spray pattern with the VR145 showerhead is 6 L/min
Form
Surface mounted shower mixer valve, vandal resistant shower head and rigid riser pipe
PressureMaximum
5.0 Bar
PressureMaximumPressureLossRatio
Should not exceed 10:1 in favour of either supply during flow
PressureMaximumStatic
10.0 Bar
PressureMinimum
0.15 Bar
TemperatureControlManufacturerNote
In the event of loss of either supply, the valve will automatically shut off
TemperatureControlMinimumBlendTemperatureDifferential
12°C to either supply
TemperatureControlTemperatureMaximum
Factory set at approximately 41°C, but this can be reset on site if required (by an authorised person)
TemperatureControlThermostaticControl
±1°C within the range 35°C to 45°C (assuming supplies of 15°C cold, 65°C hot at nominally equal pressures)
TemperatureRangeColdWaterRange
5°C to 20°C (recommended)
TemperatureRangeHotWaterRange
55°C to 65°C (recommended)
TemperatureRangeManufacturerNote
For reasons of general safety, hot water storage temperatures should be maintained at between 60°C - 65°C where serving ablutionary applications. The mixing valve can accept temporary excursions above 85°C without damage, however operation at such elevated temperatures is not recommended
ThirdPartyCertification
Buildcert TMV2 Scheme Approved, WRAS Approved
WaterSupplyTemperatureMaximum
85°C
Pset_ValveTypeCommon
Pset_ValveTypeMixing

More information

  • NBS specification data
  • More BIM objects