Electrically operated, bi-Folding industrial door with high insulation values available in a range of colours. The Swift door consist of solid, polyurethane filled panels that are hinged at the jamb. The panels can incorporate varying window sizes and are locked in the close position using 1 No. drive unit per door half.

Platform Compatible Version Certified to
IFC IFC - 1 2.0
Revit Revit 2017 + 1 2.0

  • Properties and values
  • More information
  • More BIM objects
  • What's Changed?

Properties and values

IFC
IfcExportAs
IfcDoorType
IfcExportType
DOOR
COBie
BOS_General
NBS_Data
Accessories
Photocells, traffic lights, opening safety sensors, safety edges
AirPermeability
Class 2
Applications
Emergency services bays, military vehicle garages, workshops, loading bays, power stations
Arrangement
Side hung, bifolding
ControlLogicOptionOne
FAAC E145 Control board factory set to logic E semi-automatic, Run / Stop push button unit - single push to open, single push to close, stop button stops and holds doors
ControlLogicOptionTwo
FAAC E145 Control board factory set to logic S automatic, Run / Stop push button unti - single push to open, automatic closing after pre-set pause time (default 60 seconds), stop button stops, and holds doors
ControlLogicStandard
FAAC E145 Control board factory set to logic C deadman, Run / Stop push button unit - continuous push to open, continuous push to close
DoorLeavesConstruction
Panels are constructed from 1.6mm thick cold rolled galvanised dovetail channel frames with 5 mm thick local reinforcement for hardware, the frame is covered on both sides with 0.7 mm thick galvanised steel sheets and pressure injected with CFC-free polyurethane foam to form an extremely strong, rigid, flat panel
DoorSealing
Flexible EPDM rubber seals
DriveSystemOptionOne
A faac 560 electro-hydraulic motor is mounted internally at the top of each leading edge leaf with a manual release arm fitted to each motor to engable manual operation of a door
DriveSystemStandard
A FAAC 560 electro-hydraulic motor is mounted internally at the top of each leading edge leaf with a manual release arm fitted to each motor to engable manual operation of a door
FinishOptionOne
Outside faces of panels are colourcoat LG Plastisol coated galvanised steel sheets in a choice of 40 stock RAL colours, inside face in LG plastisol in white, all hinges and drop bolt sleeves are black polyester powder coated in RAL 9005 (M)
FinishOptionTwo
Inside and / or outside faces of panels are polyester powder coated in a choice of 40 stock RAL colours, all hinges and drop bolt sleeves are black polyester powder coated in RAL 9005 (M)
Hardware
n/a
HeadroomRequired
150 mm
InsidePanelFaces
LG plastisol in white
IntermediateHinges
Machined from solid aluminium extrusions, fitted with sealed for life igus bushes and 16 mmØ stainless steel hinge pins
JambHinges
Door weight supported by two pairs of jamb hinges
LockingAndHandlesOptionOne
A lever operated floor bolt is fitted internally between pairs of leaves and is electrically interlocked
LockingAndHandlesStandard
A black thermoplastic easy-grip pull handle is fitted internally between each pair of leaves. An electro hydraulic lock within the drive motor automatically holds the door in the closed position, a small lever fitted at high level to the motor body disengages the drive, and allows the door to be opened manually, a bottom guide pin engages with a cast aluminium floor shoe fitted to the threshold, and holds the leading edge firm, a black hermoplastic easy-grip pull handle is fitted internally,
MaxDoorArea
24 m²
MotorPower
2 x 220W
OpeningSpeed
5 seconds
Operation
Powered
OperationalControlsOptions
Additional Push button, keyswitch, digi-key, radio contol, movement sensor
PanelUValue
0.40 w/m²/°C
PowerSupply
230 v, 50 hz, single phase
SafetyFeatures
Opening Safety Sensors - Infrared presence detection sensors are fitted to the inside face of the trailing edge leaf to each door half to prevent the door impacting / crushing a person or object during movement, an active infrared detector is fitted externally above the centre of the opening to prevent the door impacting / crushing a person or object during movement, in the event of any detection during door movement, the door half will stop, ,
SafetyFeaturesOptions
Safety edges - (standard with ControlLogicOptionOne and ControlLogicOptionTwo) a full height opto-electronic safety edge is mounted within each leading edge seal of the door, an impact on the edge during closing will automatically stop and re-open the door, safety edges are continuously monitored so the door cannot close automatically in the event of damage or failure of the edge, , Photocells, A FAAC XP15W send / receive photocell is fitted across the opening, the receiver unit is fitted with a long-life battery to avoid hard wiring, photocells can be fitted for closing safety, opening safety, or a combination of opening and closing. If a closing safety beam is broken during the closing cycle, the door will automatically stop and re-open, if an opening safety beam is broken during the opening cycle, the door will automatically stop, , Traffic lights, A red and green 24V DC LED traffic light unit is fitted. The unit is sized 370mm x 190mm with 24 LEDs to each light, and is intended to be mounted directly on the inside face of the door or onto a traffic light post. Sequence of operation is Red light on when door closed or part closed, Green light on when door fully open. A pair of 24Vdc limit switches is supplied to monitor the fully open position, , Photocell / traffic light posts, A pair of 100x100 RHS right angle steel posts are fitted on the inside of the bunched door leaves to mount an internal photocell and / or traffic lights, posts are painted yellow for maximum visibility,
SideroomRequired
225 mm
SurroundFrameOptionOne
Rear mounted frame - 150 x 75 x 10 RSA (angle) goalpost frame for fixing to the back of an opening painted in 100μDFT Leighs Epigrip C400 zinc phosphate primer and 75μDFT Leighs Resistex C137 acrylic urethane semi-gloss to match the door leaves, supplied with suitable anchor fixings
SurroundFrameOptionTwo
Between wall frame - 200 x 100 x 5 RHS (box) goalpost frame for fixing between walls, painted in 100μDFT Leighs Epigrip C400 zinc phosphate primer and 75μDFT Leighs Resistex C137 acrylic urethane semi-gloss to match the door leaves, supplied with suitable anchor bolt fixings
SurroundFrameStandard
Supplied by others
ThresholdPlateOptionOne
No threshold supplied
ThresholdPlateStandard
A 140 x 10 mm thick extruded aluminium plate with 30° chamfered edges and anti-slip grooves fixes directly to the floor to form a water bar, presents a level surface for the door to seal against, minimises bottom seal wear as the door folds, and provides a solid location point for floor bolts
TopGuideRollers
Nylon guide wheels running on steel shafts mounted within black aluminium extrusions
TopGuideTrack
A galvanised steel channel mounted back to the surround frame with 6 mm pressed steel brackets
TrackSystem
Top guide track, threshold plate at the floor
VisionPanelsOptionOne
Black thermoplastic snap-lock window with integral double-glazed units (2.5~15~2.5) SAN RS UV (scratch and uv resistant) outside, PMMA UV inside
VisionPanelsOptionTwo
Thermally broken aluminium window frame with one-piece inner liner tray, window units are double glazed (4~20~4), argon filled, low e toughened glass, frames are polyester powder coated in matt black to RAL 9005 (M)
VisionPanelsStandard
None fitted
Weight
20 kg/m²
WicketDoorOptionOne
Lever furniture, wicket door opens outwards, hardware comprises a Briton 5520 mortise sashlock, 25 mm low-profile anodised aluminium lever handles, external europrofile cylinder with internal thumbturn, 1½ pairs of stainless steel butt hinges and a hidden door limiting stay, 85 mm high step with 40 mm wide aluminium threshold strip
WicketDoorOptionTwo
Emergency escape furniture, wicket door opens outwards, hardware comprises a briton 379 panic bar, external override cylinder and finger latch 1½ pairs stainless steel butt hinges and a hidden overhead door limiting stay, 85 mm high step with 40 mm wide aluminium threshold strip
WicketDoorStandard
None fitted
WindowFrameSizeOptions
400 x 600 mm, 600 x 600 mm, 400 x 1200 mm, 600 x 1200 mm, 770 x 430 mm
WindPressure
Wind pressure(²) - 0.7 kn/m² (6 m high door), 1.1 kn/m² (5 m high door), 1.7 kN/m² (4 m high door), 3.1kN/m² (3m high door),
Pset_DoorWindowGlazingType

More information